Compare Products

Hide

Clear All

VS

Home> Support> Downloads>

Ruijie RG-N18000-X Series Switch RGOS11.3(1)B9 Firmware

2019-12-06 View:
Please rate this document

Please rate this document.

* This field is required.

Please leave your suggestions here.

200 characters left

If Ruijie may contact you for more details, please leave your contact information here.

* I understand and agree to Terms of Use and acknowledge Ruijie's Privacy Policy.

* This field is required.
Send Feedback

Thank you for your feedback!

Catalog
RG-S8600E Series Switch RGOS Release Notes,11.0(4)B4P3 V2.2

 

 

 

 

 

RG-N18000-X Series SwitchRGOS Release Notes,

11.3(1)B9

 

 


Release Date: March 8, 2018

 

 

 

 



Contents

This document includes the followingsections:

n Basic Information

n HardwareSupported

n Resolved Issues

n RelatedDocumentation

n Upgrade Files

n Upgrade Tips

Basic Information

Table 1 lists the basic information of thecurrent release.

Table 1 Basic Information of the CurrentRelease

Current Release

N18000-X_RGOS11.3(1)B9

Previous Release

N18000-X_ RGOS 11.3(1)B4

Applicable Product

RG- N18018-X, RG-N18010-X

Category

Official release

 

Use the show version command todisplay information about the software version.

dut2#shoversion

Systemdescription      : Ruijie High-density IPv6 100G CoreRouting Switch(N18010-X) By Ruijie Networks

Systemstart time       : 2034-04-25 06:42:06

Systemuptime           :14:17:50:31

Systemhardware version : 1.10

Systemsoftware version : N18000-X_RGOS 11.3(1)B9

Systempatch number     : NA

Systemserial number    : G1L2057000400

Systemboot version     : 1.2.22

Moduleinformation:

 Slot M1 : M18000X-CM II

   Hardware version    : 1.10

   Boot version        : 1.2.22

   Software version    : N18000-X_RGOS 11.3(1)B9

   Serial number       : G1L2057000400

 Slot 1 : M18000X-12QXS12CQ-CB

   Hardware version    : 1.00

   Boot version        : 1.2.22

   Software version    : N18000-X_RGOS 11.3(1)B9

   Serial number       : 1234942570028

 Slot 2 : M18000X-18QXS18CQ-CB

   Hardware version    : 1.00

   Boot version        : 1.2.22

   Software version    : N18000-X_RGOS 11.3(1)B9

   Serial number       : 1234942570020

 Slot 3 : M18000X-6QXS6CQ-CB

   Hardware version    : 1.00

   Boot version        : 1.2.22

   Software version    : N18000-X_RGOS 11.3(1)B9

   Serial number       : 1234942570014

 Slot 4 : M18000X-6QXS6CQ-CB

   Hardware version    : 1.00

   Boot version        : 1.2.22

   Software version    : N18000-X_RGOS 11.3(1)B9

   Serial number       : 1234942570023

 Slot 5 : M18000X-48XS2CQ-CB

   Hardware version    : 1.00

   Boot version        : 1.2.22

   Software version    : N18000-X_RGOS 11.3(1)B9

   Serial number       : 1234942570015

 Slot 6 : M18000X-6QXS6CQ-CB

   Hardware version    : 1.00

   Boot version        : 1.2.22

   Software version    : N18000-X_RGOS 11.3(1)B9

   Serial number       : 1234942570017

 Slot FE1 : M18010X-FE-C I

   Hardware version    : 1.00

   Boot version        : 1.2.22

   Software version    : N18000-X_RGOS 11.3(1)B9

   Serial number       : G1KS83Q000065

 

 

dut2#shover detail

Systemdescription      : Ruijie High-density IPv6 100G CoreRouting Switch(N18010-X) By Ruijie Networks

Systemstart time       : 2034-04-25 06:42:06

Systemuptime           :14:17:50:54

Systemhardware version : 1.10

Systemsoftware version : N18000-X_RGOS 11.3(1)B9

Systempatch number     : NA

Systemsoftware number  : M01411508242017

Systemserial number    : G1L2057000400

Systemboot version     : 1.2.22.917a8a0(160718)

Systemcore version     : 2.6.32.cc45751d6ca85d

System cpupartition    : 8-31

Moduleinformation:

 Slot M1 : M18000X-CM II

   Hardware version    : 1.10

   Boot version        : 1.2.22.917a8a0(160718)

   Software version    : N18000-X_RGOS 11.3(1)B9

   Software number     : M01411508242017

   Serial number       : G1L2057000400

 Slot 1 : M18000X-12QXS12CQ-CB

   Hardware version    : 1.00

   Boot version        : 1.2.22.69aa19a(160612)

   Software version    : N18000-X_RGOS 11.3(1)B9

   Software number     : M00455908242017

   Serial number       : 1234942570028

 Slot 2 : M18000X-18QXS18CQ-CB

   Hardware version    : 1.00

   Boot version        : 1.2.22.69aa19a(160612)

   Software version    : N18000-X_RGOS 11.3(1)B9

   Software number     : M00455908242017

   Serial number       : 1234942570020

 Slot 3 : M18000X-6QXS6CQ-CB

   Hardware version    : 1.00

   Boot version        : 1.2.22.69aa19a(160612)

   Software version    : N18000-X_RGOS 11.3(1)B9

   Software number     : M00455908242017

   Serial number       : 1234942570014

 Slot 4 : M18000X-6QXS6CQ-CB

   Hardware version    : 1.00

   Boot version        : 1.2.22.69aa19a(160612)

   Software version    : N18000-X_RGOS 11.3(1)B9

   Software number     : M00455908242017

   Serial number       : 1234942570023

 Slot 5 : M18000X-48XS2CQ-CB

   Hardware version    : 1.00

   Boot version        : 1.2.22.69aa19a(160612)

   Software version    : N18000-X_RGOS 11.3(1)B9

   Software number     : M00455908242017

   Serial number       : 1234942570015

 Slot 6 : M18000X-6QXS6CQ-CB

   Hardware version    : 1.00

   Boot version        : 1.2.22.69aa19a(160612)

   Software version    : N18000-X_RGOS 11.3(1)B9

   Software number     : M00455908242017

   Serial number       : 1234942570017

 Slot FE1 : M18010X-FE-C I

   Hardware version    : 1.00

   Boot version        : 1.2.22.69aa19a(160612)

   Software version    : N18000-X_RGOS 11.3(1)B9

    Softwarenumber     : M00455908242017

   Serial number       : G1KS83Q000065

Hardware Supported

Table 2 shows the hardware supported bythe RGOS 11.3(1)B9.

Table 2 Supporting Hardware Models

Hardware Model

Version

Description

RG-N18018-X

1.0

Chassis

RG-N18010-X

1.0

Chassis

M18000X-CM II

1.0

Supervisor module

M18018X-FE-C II

1.0

Switch fabric module

M18010X-FE-C I

1.0

Switch fabric module

M18000X-48XS2CQ-CB

1.0

Line card

M18000X-6QXS6CQ-CB

1.0

Line card

M18000X-12QXS12CQ-CB

1.0

Line card

M18000X-18QXS18CQ-CB

1.0

Line card

M18000X-48XT2CQ-CB

1.0

Line card

RG-PA2700I

1.0

Power supply module

 

*     The hardware version number is rounded to thefirst decimal place. The numeral in the second decimal place does not changethe supporting release.

*     For detail, see RG-N18000-X Series SwitchHardware Installation and Reference Guide V1.13.

Resolved Issues

This section describes the fixed bugs.

Table 3 Fixed Bugs Based on 11.3(1)B9

No.

Bug Description

1

When BGP/BFD/ a great number of routes are configured, one-key upgrade causes traffic interruption for 113s.

2

High CPU usage may cause an incorrect temperature of the line card displayed in the output of the show temp command.

3

Frequent flapping of ECMP routes may cause failure to ping some neighbors.

4

Occasional suspending of the bridge thread on the supervisor module may cause service interruption.

5

If BGP enables multiple VRF instances, the downlink neighbor may be restarted, and traffic interruption may occur occasionally for several seconds.

6

The clear ip ospf process command causes BFD flapping.

7

If an inactive default route exists, when the outbound interface is down, BGP route convergence is slow.

8

If a recursive query shows that the next route of the BGP route is an IGP route, and an active default route exists, when IGP goes up and down, the NSM process occasionally restarts.

9

When a 40 Gbps copper cable is connected to a 100 Gbps port, error information is displayed.

10

When the physical port of the active chassis in a VSU is down, an active/standby switchover is immediate performed and may cause an incorrect state of the new physical port.

11

When CPU usage of the supervisor module is high, if a line card is started in hot startup mode, ports on the line card may fail to go up.

12

When a VSU is restarted, ports on the panel may fail to go up and be enabled at a low probability.

13

When the VSL card is restarted after the AP is switched to a larger-capacity mode, ports on the standby switch may fail to be pinged at a low probability.

14

When an ACL applies to the outbound direction of an SVI, restarting the SSC process or the reloaded device may fail to take effect.

15

When you configure an enhanced load-balancing template L2 or IPv4/IPv6 source port factor, and change the hash mode from non-enhanced to enhanced, ECMP fails to perform load balancing based on the source port.

16

After modifying the AP mode, you need to manually restart the AP twice to use it properly.

17

If a line card is started in hot startup mode when the system is busy, data synchronization may fail to be triggered, and ports cannot go up.

 

*     For detail, see Bug Notice.

Changed Features

Table 4 HardwareChange

Hardware Model

Version Number

Description

M18000X-6QXS6CQ-CB

1.0

Line card is supported

M18000X-12QXS12CQ-CB

1.0

Line card is supported

M18000X-18QXS18CQ-CB

1.0

Line card is supported

M18000X-48XT2CQ-CB

1.0

Line card is supported

Table 5 New Feature

Module

VSU

New Feature

VSU on N18010-X

CLI Change

N/A

Web Change

N/A

MIB Change

N/A

Related Documentation

n RG-N18000-X Series Switch Hardware Installationand Reference Guide 1.13
This manual introduces the functional and physical features of the N18000-Xseries switch and provides the device installation steps, hardwaretroubleshooting, module technical specifications, and specifications and usageguidelines for cables and connectors. 

n RG-N18000-X Series Switch RGOS ConfigurationGuide, Release 11.3(1)B9
This manual describes the various network protocols and their implementationprinciples for the RG-N18000-X series with the detailed configuration examples.

n RG-N18000-X Series Switch RGOS CommandReference, Release 11.3(1)B9
This manual describes the configuration commands related to the various networkprotocols supported on the RG-N18000-X series switch RGOS
11.3(1)B9 version in detail, including thecommand mode, parameter description, usage guide, and configuration examples.

 

*     You can obtain the related documents at: http://www.ruijienetworks.com/.

Upgrade Files

Table 6 LatestUpgrade Firmware

Applicable Model

Upgrade Firmware

File Size

MD5

M18000X-CM II

N18000-X_RGOS11.3(1)B9_CMXII_install.bin

211,173,195 bytes

480f6e699499d3133f442d9481907bcd

Upgrade Tips

The following are some tips for upgradingthe RG-N18000-X Series Switch RGOS 11.3(1)B9:

n During the upgrade and downgrade, pay attentionto the prompt messages. If failures occur, please save the log and contact usfor technical assistance.

n During the upgrade and downgrade, it isrecommended you not power off or reset the system, or plug/unplug any module.

n Use the show version command to check thefirmware after the upgrade/downgrade.

Ruijie Networks websites use cookies to deliver and improve the website experience.

See our cookie policy for further details on how we use cookies and how to change your cookie settings.

Cookie Manager

When you visit any website, the website will store or retrieve the information on your browser. This process is mostly in the form of cookies. Such information may involve your personal information, preferences or equipment, and is mainly used to enable the website to provide services in accordance with your expectations. Such information usually does not directly identify your personal information, but it can provide you with a more personalized network experience. We fully respect your privacy, so you can choose not to allow certain types of cookies. You only need to click on the names of different cookie categories to learn more and change the default settings. However, blocking certain types of cookies may affect your website experience and the services we can provide you.

  • Performance cookies

    Through this type of cookie, we can count website visits and traffic sources in order to evaluate and improve the performance of our website. This type of cookie can also help us understand the popularity of the page and the activity of visitors on the site. All information collected by such cookies will be aggregated to ensure the anonymity of the information. If you do not allow such cookies, we will have no way of knowing when you visited our website, and we will not be able to monitor website performance.

  • Essential cookies

    This type of cookie is necessary for the normal operation of the website and cannot be turned off in our system. Usually, they are only set for the actions you do, which are equivalent to service requests, such as setting your privacy preferences, logging in, or filling out forms. You can set your browser to block or remind you of such cookies, but certain functions of the website will not be available. Such cookies do not store any personally identifiable information.

Accept All

View Cookie Policy Details

Contact Us

Contact Us

How can we help you?

Contact Us

Get an Order help

Contact Us

Get a tech support

2024 Ruijie Networks Brand Awareness Survey

Your opinions and feelings are crucial for our improvement.

Fill in the survey