Ruijie RG-CS86-20XS Series Switches CS86_RGOS 12.6(2)B0104
|
|
||
|
Release Notes
|
|
||
|
|
|||
Document Version: V1.3
Date: 2023.05.16
Copyright © 2023 Ruijie Networks
|
|
|||
Copyright
Copyright © 2023 Ruijie Networks
All rights are reserved in this document and this statement.
Any reproduction, excerption, backup, modification, transmission, translation or commercial use of this document or any portion of this document, in any form or by any means, without the prior written consent of Ruijie Networks is prohibited.
Trademark
All other trademarks or registered trademarks mentioned in this document are owned by their respective owners.
Disclaimer
The products, services, or features you purchase are subject to commercial contracts and terms. Some or all of the products, services or features described in this document may not be within the scope of your purchase or use. Unless otherwise agreed in the contract, Ruijie Networks does not make any express or implied statement or guarantee for the content of this document.
Due to product version upgrades or other reasons, the content of this document will be updated from time to time. Ruijie Networks reserves the right to modify the content of the document without any notice or prompt.
This manual is for reference only. Ruijie Networks endeavors to ensure content accuracy and will not shoulder any responsibility for losses and damages caused due to content omissions, inaccuracies or errors.
Intended Audience
This document is intended for:
l
Network engineers
l
Technical support and servicing engineers
l
Network administrators
Technical Support
l
Ruijie Networks Website: https://www.ruijienetworks.com/
l
Technical Support Website: https://ruijienetworks.com/support
l
Case Portal: https://caseportal.ruijienetworks.com
l
Community: https://community.ruijienetworks.com
l
Technical Support Email: service_rj@ruijienetworks.com
l
Skype: service_rj@ruijienetworks.com
Conventions
1.
Conversions
Convention
|
Description
|
Bold font
|
Commands, command options, and keywords are in bold font.
|
Italic font
|
Arguments for which you supply values are in italic font.
|
[ ]
|
Elements in square brackets are optional.
|
{ x | y | z }
|
Alternative keywords are grouped in braces and separated by vertical bars.
|
[ x | y | z ]
|
Optional alternative keywords are grouped in brackets and separated by vertical bars.
|
&<1-n>
|
The argument before the sign (&) can be input for consecutive 1- n times.
|
//
|
Double slashes at the beginning of a line of code indicate a comment line.
|
1.
Signs
The signs used in this document are described as follows:
Warning
An alert that calls attention to important rules and information that if not understood or followed can result in data loss or equipment damage.
Caution
An alert that calls attention to essential information that if not understood or followed can result in function failure or performance degradation.
Note
An alert that contains additional or supplementary information that if not understood or followed will not lead to serious consequences.
Specification
An alert that contains a description of product or version support.
RGOS 12.6(2)B0104
|
|
Applicable Products
|
RG-CS86-20XS4VS2QXS-D
|
Category
|
Official Release
|
Customers
|
Global customers
|
Release Date
|
2023-04-12
|
Baseline Version
|
NA
|
Reason for Release
|
The RG-CS86-20XS4VS2QXS-D switch running this release can be managed by Ruijie Cloud.
|
Use the show version detail command to check the version number.
Ruijie#show version detail
System description : Ruijie 10G Ethernet Switch(CS86-20XS4VS2QXS-D) By Ruijie Networks
System start time : 2023-04-12 10:40:31
System uptime : 00:02:48:23
System hardware version : 1.00
System software version : CS86_RGOS 12.6(2)B0104
System patch number : NA
System software number : M04323004102023
System serial number : MACC304111704
System boot version : 1.4.17(Master) 1.4.17(Slave)
System rboot version : 1.1.39
System core version : 4.4.178-dirty
Module information:
Slot 0 : CS86-20XS4VS2QXS-D
System uptime : 00:02:48:23
Hardware version : 1.00
Boot version : 1.4.17(Master) 1.4.17(Slave)
Rboot version : 1.1.39
Software version : CS86_RGOS 12.6(2)B0104
Software number : M04323004102023
Serial number : MACC304111704
Note
After the version was released, the upgrade file may be released (identified by ID) because bugs were found and resolved.
Release Date
|
Upgrade File
|
Description
|
2023-3-23
|
CS86-20XS_RGOS12.6(2)B0104_install.bin
|
Pilot release for the RG-CS86-20XS4VS2QXS-D switch
|
2023-04-12
|
CS86-20XS_RGOS12.6(2)B0104_install.bin
|
Official release for the RG-CS86-20XS4VS2QXS-D switch
|
Bug ID
|
761952
|
Description
|
When configuring the VLAN ID range-based selective QINQ, there should be no more than 8 VLAN IDs in each range. For example, for the C-TAG based QINQ, the command dot1q outer vid 20 register inner vid 1-8,1-10,12-15 successfully configures two VLAN ID ranges (range 1-8 and range 12-15), and range 1-10 fails to be configured.
|
Workaround
|
Perform integrated service planning to avoid assigning discrete VLANs to different services.
|
Release
|
RGOS12.5(4)B1102
|
Bug ID
|
881776
|
Description
|
l
On Ruijie Cloud, the port rate options of a 25 Gbps port includes 1000 Mbps. However, the actual 25 Gbps port on the switch does not support the 1000 Mbps port rate.
l
When the port rate of a 25 Gbps port on Ruijie Cloud is configured as 10Gbps/25G Gbps, a succes message will be displayed on the Ruijie Cloud, but the configruation does not take effect on the switch.
|
Workaround
|
Do not configure the port rate of a 25 Gbps port on Ruijie Cloud.
|
Release
|
RGOS12.5(4)B1102
|
Note
The hardware version number is rounded to the first decimal place. The numeral in the second decimal place does not change the supporting release.
Hardware Model
|
Version Number
|
|
Chassis
|
RG-CS86-20XS4VS2QXS-D
|
1.0
|
Note
Version
|
Baseline
|
Description
|
RGOS12.6(2)B0104
|
NA
|
Official release for CS86-20XS switches
|
Hardware Type
|
Hardware Model
|
Version Number
|
Chassis
|
RG-CS86-20XS4VS2QXS-D
|
1.0
|
The RG-CS86-20XS4VS2QXS-D switch running this release can be managed by the Ruijie Cloud.
To upgrade the device to this version, the following upgrade files are required.
Upgrade File
|
CS86-20XS_RGOS12.6(2)B0104_install.bin
|
File Description
|
Installation Package
|
File Size
|
131801067 Bytes
|
Applicable Product
|
RG-CS86-20XS4VS2QXS-D
|
MD5
|
5da3c187c522542d6fe8f95cd8bc38d4
|
Software Version
|
RGOS 12.6(2)B0104
|
NA
l
During the upgrade and downgrade, pay attention to the prompts. If failures occur, please save the log and contact us for technical assistance.
l
During the upgrade and downgrade, you are advised not to power off the device, reset the system, or plug in/unplug any module if the related prompts are displayed.
l
After the upgrade and downgrade, run the show version command to view the current version of the device and check the firmware.
(1)
Run the CLI command on the PC configured with IP address x.x.x.x (The following bin file name is just an example.):
Ruijie# upgrade download oob_tftp://x.x.x.x/ CS86-20XS_RGOS12.6(2)B0104_install.bin
*May 14 10:32:20: %UPGRADE-6-INFO: Copy to /data/upgrade_rep/
*May 14 10:32:20: %UPGRADE-6-INFO: Please wait for a moment......
Press Ctrl+C to quit
!!!!!!!!!!!!!!!!!!!!!!!!!!!...
< The terminal is locked by upgrade module >
Upgrade start
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!10%
< you can press Ctrl+C to unlock terminal >
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!20%
< you can press Ctrl+C to unlock terminal >
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!30%
< you can press Ctrl+C to unlock terminal >
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!40%
< you can press Ctrl+C to unlock terminal >
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!50%
< you can press Ctrl+C to unlock terminal >
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!60%
< you can press Ctrl+C to unlock terminal >
!!!!!!!!100%
Upgrade success <- When you see the prompt “Upgrade finish”, the copy operation is complete (The BIN file takes effect only after the device is restarted).
< The terminal is unlocked by upgrade module >
[Slot 0]
Device type : cs86
Status : success
(2)
Restart the device after the upgrade is complete to validate the BIN file.
Ruijie#reload
Reload system?(Y/N)y
Ruijie#*May 14 12:51:02: %DP-3-RESET_DEV: Reset device 1 due to SYSMON/4215/CONSOLE/reset system by reload command.
*May 14 12:51:02: %DP-3-MACHINE_RESTART: MACHINE_RESTART.
[504172.116141] %SYS-0-REBOOT: Rebooting by job: dp_mom_thread/4265
[504172.126545] reboot: Restartin
U-Boot 1.4.14-gc4283be (Mar 21 2020 - 21:56:04 +0800)
Clock Configuration:
CPU0(A53):1200 MHz CPU1(A53):1200 MHz
Bus: 500 MHz DDR: 1600 Mbps
DRAM: 1 GiB (DDR4, 16-bit, CS=2, ECC on)
Flash: SF: Detected mx25l25635f with page size 256 Bytes, erase size 64 KiB, total 32 MiB
SF: Detected mx25l25635f with page size 256 Bytes, erase size 64 KiB, total 32 MiB
32 MiBMMC: Only Support 3.3 voltage
sdhci@30400000: 0
Loading Environment from SPI Flash... OK
Boot: Master
Net: eth0: ethernet@33410000
Press Ctrl+B to enter Boot Menu, Press Ctrl+C to enter Rboot 0
14 bytes read in 2 ms (6.8 KiB/s)
33 bytes read in 2 ms (15.6 KiB/s)
6814976 bytes read in 150 ms (43.3 MiB/s)
8422045 bytes read in 184 ms (43.7 MiB/s)
36561 bytes read in 3 ms (11.6 MiB/s)
starting pid 1179, tty '': '-/etc/sysinit'
starting initrd
Switching rootfs
[ 1.258085] TIPC: Activated (version 2.0.0)
[ 1.258546] TIPC: Started in single node mode
log: connected to ubus
Press RETURN to get started
(3)
Run the “show version detail” command to confirm the upgrade success.
Ruijie#show version detail
System description : Ruijie 10G Ethernet Switch(CS86-20XS4VS2QXS-D) By Ruijie Networks
System start time : 2023-04-12 10:40:31
System uptime : 00:02:48:23
System hardware version : 1.00
System software version : CS86_RGOS 12.6(2)B0104
System patch number : NA
System software number : M04323004102023
System serial number : MACC304111704
System boot version : 1.4.17(Master) 1.4.17(Slave)
System rboot version : 1.1.39
System core version : 4.4.178-dirty
Module information:
Slot 0 : CS86-20XS4VS2QXS-D
System uptime : 00:02:48:23
Hardware version : 1.00
Boot version : 1.4.17(Master) 1.4.17(Slave)
Rboot version : 1.1.39
Software version : CS86_RGOS 12.6(2)B0104
Software number : M04323004102023
Serial number : MACC304111704
(1)
Run the “upgrade usb0:/xxx.bin” command.
Ruijie# upgrade usb0:/ CS86-20XS_RGOS12.6(2)B0104_install.bin
< The terminal is locked by upgrade module >
Upgrade start
!!!Running this command may take some time, please wait.
!!!!!!!!!!!!!!!!!!!!!!!!!!!10%
< you can press Ctrl+C to unlock terminal >
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!20%
< you can press Ctrl+C to unlock terminal >
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!30%
< you can press Ctrl+C to unlock terminal >
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!40%
< you can press Ctrl+C to unlock terminal >
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!50%
< you can press Ctrl+C to unlock terminal >
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!60%
< you can press Ctrl+C to unlock terminal >
100%
Upgrade success <- When the message “Upgrade finish” is displayed, the copy operation is complete (the BIN file takes effect only after the device is restarted).
< The terminal is unlocked by upgrade module >
[Slot 0]
Device type : cs86
Status : success
During the upgrade, you can run the “show upgrade status” command to check the upgrade status:
Ruijie#show upgrade status
upgrade global status: UPGRADING
[Slot 0]
Device type : cs86
Status : upgrading <- When the upgrade is complete, the message “success” is displayed.
(2)
Restart the device to validate the BIN file.
Ruijie#reload
Reload system?(Y/N)y
Ruijie#*May 14 12:51:02: %DP-3-RESET_DEV: Reset device 1 due to SYSMON/4215/CONSOLE/reset system by reload command.
*May 14 12:51:02: %DP-3-MACHINE_RESTART: MACHINE_RESTART.
[504172.116141] %SYS-0-REBOOT: Rebooting by job: dp_mom_thread/4265
[504172.126545] reboot: Restartin
U-Boot 1.4.14-gc4283be (Mar 21 2020 - 21:56:04 +0800)
Clock Configuration:
CPU0(A53):1200 MHz CPU1(A53):1200 MHz
Bus: 500 MHz DDR: 1600 Mbps
DRAM: 1 GiB (DDR4, 16-bit, CS=2, ECC on)
Flash: SF: Detected mx25l25635f with page size 256 Bytes, erase size 64 KiB, total 32 MiB
SF: Detected mx25l25635f with page size 256 Bytes, erase size 64 KiB, total 32 MiB
32 MiBMMC: Only Support 3.3 voltage
sdhci@30400000: 0
Loading Environment from SPI Flash... OK
Boot: Master
Net: eth0: ethernet@33410000
Press Ctrl+B to enter Boot Menu, Press Ctrl+C to enter Rboot 0
14 bytes read in 2 ms (6.8 KiB/s)
33 bytes read in 2 ms (15.6 KiB/s)
6814976 bytes read in 150 ms (43.3 MiB/s)
8422045 bytes read in 184 ms (43.7 MiB/s)
36561 bytes read in 3 ms (11.6 MiB/s)
starting pid 1179, tty '': '-/etc/sysinit'
starting initrd
Switching rootfs
[ 1.258085] TIPC: Activated (version 2.0.0)
[ 1.258546] TIPC: Started in single node mode
log: connected to ubus
Press RETURN to get started
(3)
Run the “show version detail” command to confirm the upgrade success.
Ruijie#show version detail
System description : Ruijie 10G Ethernet Switch(CS86-20XS4VS2QXS-D) By Ruijie Networks
System start time : 2023-04-12 10:40:31
System uptime : 00:02:48:23
System hardware version : 1.00
System software version : CS86_RGOS 12.6(2)B0104
System patch number : NA
System software number : M04323004102023
System serial number : MACC304111704
System boot version : 1.4.17(Master) 1.4.17(Slave)
System rboot version : 1.1.39
System core version : 4.4.178-dirty
Module information:
Slot 0 : CS86-20XS4VS2QXS-D
System uptime : 00:02:48:23
Hardware version : 1.00
Boot version : 1.4.17(Master) 1.4.17(Slave)
Rboot version : 1.1.39
Software version : CS86_RGOS 12.6(2)B0104
Software number : M04323004102023
Serial number : MACC304111704
(1)
Run the “@@@@b” command
Ruijie#@@@@b
[156375.133279] IRQ RESPONSES
U-Boot 1.4.14-gc4283be (Mar 21 2020 - 21:56:04 +0800)
Clock Configuration:
CPU0(A53):1200 MHz CPU1(A53):1200 MHz
Bus: 500 MHz DDR: 1600 Mbps
DRAM: 1 GiB (DDR4, 16-bit, CS=2, ECC on)
Flash: SF: Detected mx25l25635f with page size 256 Bytes, erase size 64 KiB, total 32 MiB
SF: Detected mx25l25635f with page size 256 Bytes, erase size 64 KiB, total 32 MiB
32 MiBMMC: Only Support 3.3 voltage
sdhci@30400000: 0
Loading Environment from SPI Flash... OK
Boot: Master
Net: eth0: ethernet@33410000
Press Ctrl+B to enter Boot Menu, Press Ctrl+C to enter Rboot 0
During the reboot, press Ctrl+C immediately when the following message is displayed to ask you to access the Rboot interface.
Press Ctrl+B to enter Boot Menu, Press Ctrl+C to enter Rboot 0
Rboot Version: 1.1.15
------------------------------------------------
Mount rootfs1 ...
Mount rootfs2 ...
Mount data ...
Mount upgrade ...
Mount upgrade_bak ...
====== Rboot Menu (Ctrl+Z to upper level) ======
TOP menu items.
************************************************
1. Tftp utilities.
1. X/Y/ZModem utilities.
1. Run main.
1. SetMac utilities.
1. Scattered utilities.
************************************************
Press a key to run the command:
Click the prompt in red under the Rboot menu to access the address configuration menu:
====== Rboot Menu(Ctrl+Z to upper level) ======
TOP menu items.
************************************************
1. Tftp utilities.
1. XModem utilities.
1. Run main.
1. SetMac utilities.
1. Scattered utilities.
************************************************
Press a key to run the command:
====== Rboot Menu(Ctrl+Z to upper level) ======
Tftp utilities.
************************************************
1. Upgrade uboot program.
1. Upgrade rboot program.
1. Upgrade main program.
1. Burn the total FlashROM by this downloaded file.
************************************************
Press a key to run the command:
enter the Local IP:[]:
Under the address configuration menu, enter the switch IP address, PC IP address, and BIN file name:
Press a key to run the command:
enter the Local IP:[]:192.12.1.1 <- This address is the switch IP address, configured in the same network segment as the execution PC.
enter the Remote IP:[]:192.12.1.2 <- This address is the PC IP address.
enter the Filename:[]:CS86-20XS_RGOS12.6(2)B0104_install.bin <- This file name serves as an example.
The upgrade operation starts after the preceding addresses and file name are entered:
% Total % Received % Xferd Average Speed Time Time Time Current
Dload Upload Total Spent Left Speed
147M 100 147M 0 0 1902k 0 0:01:19 0:01:19 --:--:-- 1968k
100 147M 100 147M 0 0 1902k 0 0:01:19 0:01:19 --:--:-- 1902k
Upgrading, keep power on and wait please ...
Select Y as prompted to proceed until the system displays the message “Upgrade Success” (the upgrade file is copied successfully):
Determined to upgrade? [Y/N]: Y
Mount File System ...
Copy file to Flash ...
Upgrade Rootfs Success.
Upgrade Success
After the upgrade file is copied successfully, it automatically returns to the Rboot menu interface. Press Ctrl+Z to exit the menu for reboot. (You can also directly power off and restart the device.):
====== Rboot Menu(Ctrl+Z to upper level) ======
Tftp utilities.
************************************************
1. Upgrade uboot program.
1. Upgrade rboot program.
1. Upgrade main program.
1. Burn the total FlashROM by this downloaded file.
************************************************
Press a key to run the command:
====== Rboot Menu(Ctrl+Z to upper level) ======
TOP menu items.
************************************************
1. Tftp utilities.
1. XModem utilities.
1. Run main. <- Select Run main, and the switch will automatically restart.
1. SetMac utilities.
1. Scattered utilities.
************************************************
Wait for the device to restart:
*May 14 12:51:02: %DP-3-MACHINE_RESTART: MACHINE_RESTART.
[504172.116141] %SYS-0-REBOOT: Rebooting by job: dp_mom_thread/4265
[504172.126545] reboot: Restartin
U-Boot 1.4.14-gc4283be (Mar 21 2020 - 21:56:04 +0800)
Clock Configuration:
CPU0(A53):1200 MHz CPU1(A53):1200 MHz
Bus: 500 MHz DDR: 1600 Mbps
DRAM: 1 GiB (DDR4, 16-bit, CS=2, ECC on)
Flash: SF: Detected mx25l25635f with page size 256 Bytes, erase size 64 KiB, total 32 MiB
SF: Detected mx25l25635f with page size 256 Bytes, erase size 64 KiB, total 32 MiB
32 MiBMMC: Only Support 3.3 voltage
sdhci@30400000: 0
Loading Environment from SPI Flash... OK
Boot: Master
Net: eth0: ethernet@33410000
Press Ctrl+B to enter Boot Menu, Press Ctrl+C to enter Rboot 0
14 bytes read in 2 ms (6.8 KiB/s)
33 bytes read in 2 ms (15.6 KiB/s)
6814976 bytes read in 150 ms (43.3 MiB/s)
8422045 bytes read in 184 ms (43.7 MiB/s)
36561 bytes read in 3 ms (11.6 MiB/s)
starting pid 1179, tty '': '-/etc/sysinit'
starting initrd
Switching rootfs
[ 1.258085] TIPC: Activated (version 2.0.0)
[ 1.258546] TIPC: Started in single node mode
log: connected to ubus
Press RETURN to get started
(2)
Run the “show version detail” command to check whether the upgrade is successful.
Ruijie#show version detail
System description : Ruijie 10G Ethernet Switch(CS86-20XS4VS2QXS-D) By Ruijie Networks
System start time : 2023-04-12 10:40:31
System uptime : 00:02:48:23
System hardware version : 1.00
System software version : CS86_RGOS 12.6(2)B0104
System patch number : NA
System software number : M04323004102023
System serial number : MACC304111704
System boot version : 1.4.17(Master) 1.4.17(Slave)
System rboot version : 1.1.39
System core version : 4.4.178-dirty
Module information:
Slot 0 : CS86-20XS4VS2QXS-D
System uptime : 00:02:48:23
Hardware version : 1.00
Boot version : 1.4.17(Master) 1.4.17(Slave)
Rboot version : 1.1.39
Software version : CS86_RGOS 12.6(2)B0104
Software number : M04323004102023
Serial number : MACC304111704
Note
The related documents are subject to change or update without prior notification. Please follow the official website of Ruijie Network https://www.ruijienetworks.com/.
File name
|
Description
|
Ruijie RG-CS86-20XS Series Switches Release Notes, RGOS 12.6(2)B0104
|
This manual introduces CS86_RGOS 12.6(2)B0104 version, including: version information, resolved issues, remaining Issues, hardware support, version change record, upgrade instructions, and Related Documentation.
|
Ruijie RG-CS86-20XS Series Switches Configuration Guide, RGOS 12.6(2)B0104
|
This manual describes various network protocols and their implementation principles supported by CS86_RGOS 12.6(2)B0104 with detailed configuration examples.
|
Ruijie RG-CS86-20XS Series Switches Command Reference, RGOS 12.6(2)B0104
|
This manual describes all configuration commands supported by CS86_RGOS 12.6(2)B0104 version, including the command modes, parameter descriptions and usage guidelines with specific examples.
|
Ruijie RG-CS86-20XS Series Switches Web-based Configuration Guide, RGOS 12.6(2)B0104
|
This manual describes how to configure the functions supported by CS86_RGOS 12.6(2)B0104 through the Web management system with detailed configuration examples.
|
Ruijie RG-CS86-20XS Series Switches Hardware Installation and Reference Guide
|
This manual describes the functional and physical features of the RG-CS86-20XS4VS2QXS-D switches and provides equipment installation procedures, hardware troubleshooting, technical specifications of module, as well as the specifications and usage guidelines of cables and connectors.
|
How do you like this document ?
Ruijie Networks websites use cookies to deliver and improve the website experience.
See our cookie policy for further details on how we use cookies and how to change your cookie settings.
Cookie Manager
When you visit any website, the website will store or retrieve the information on your browser. This process is mostly in the form of cookies. Such information may involve your personal information, preferences or equipment, and is mainly used to enable the website to provide services in accordance with your expectations. Such information usually does not directly identify your personal information, but it can provide you with a more personalized network experience. We fully respect your privacy, so you can choose not to allow certain types of cookies. You only need to click on the names of different cookie categories to learn more and change the default settings. However, blocking certain types of cookies may affect your website experience and the services we can provide you.
Through this type of cookie, we can count website visits and traffic sources in order to evaluate and improve the performance of our website. This type of cookie can also help us understand the popularity of the page and the activity of visitors on the site. All information collected by such cookies will be aggregated to ensure the anonymity of the information. If you do not allow such cookies, we will have no way of knowing when you visited our website, and we will not be able to monitor website performance.
This type of cookie is necessary for the normal operation of the website and cannot be turned off in our system. Usually, they are only set for the actions you do, which are equivalent to service requests, such as setting your privacy preferences, logging in, or filling out forms. You can set your browser to block or remind you of such cookies, but certain functions of the website will not be available. Such cookies do not store any personally identifiable information.
Contact Us
How can we help you?