Back

Compare Products

Hide

Clear All

VS

Picture

RG-S6510-48VS8CQ 25GE Data Center Access Switch

RDMA-capable high-density 25GE/100GE access switch for data center networks with low latency and no packet drop

Models

Series

Highlight Features

  • 48 x 25GE SFP28 ports + 8 x 100GE QSFP28 ports, and 32 MB buffer, easily coping with burst traffic
  • Cross-device link aggregation (De-stacking/M-LAG/VSU), device-level redundancy, flexible networking, and high reliability
  • Multiple hardware-level protection, ensuring service consistency and network stability
  • VXLAN tunneling technology, achieving unlimited data transmission and flexible resource allocation and scheduling
  • Lossless Ethernet, ensuring zero packet loss during RDMA E2E communication
  • Telemetry/gRPC/sFlow/SPAN-based network monitoring and automated O&M, making management simple and efficient

Key Specification

25GE Data Center Access Switch RG-S6510-48VS8CQ

8 x 25GE SFP28 ports and 8 x 100GE QSFP28 ports, delivering line-rate forwarding capacity
32 MB buffer and advanced buffer scheduling mechanism, providing fast data processing and easily coping with burst traffic

Hardware-level Redundancy, Ensuring Service Continuity

Hot-swappable redundant power modules

Hot-swappable redundant fan modules

Power modules in 1+1 redundancy mode, and failover in seconds, providing nonstop services

Cross-device Link Aggregation, Implementing Device-level Redundancy, Flexible Networking, and High Reliability

De-stacking

M-LAG

VSU

De-stacking technology logically aggregates multiple switches through LACP to allow servers on the same network segment or on different network segments to communicate. This eliminates the need to synchronize data between switches, without affecting service transmission.

VXLAN Tunneling Technology, Achieving Unlimited Data Transmission and Flexible Resource Allocation and Scheduling

VXLAN technology creates virtual tunnels on an IP network by building a virtual Layer 2 network, implementing cross-region and cross-DC data migration, and flexible resource allocation and scheduling. The switch supports EVPN VXLAN to enhance the number of tenants, meeting requirements of identification and isolation between different networks on a large scale.

PFC- and ECN-based Lossless Ethernet with High Throughput and Low Latency in RDMA Scenarios

With RDMA technology, data does not need to be handled by the CPU during device communication. This reduces the CPU burden and effectively solves the network latency problem.
PFC+ECN, intelligent data exchange, and packet loss prevention, ensuring lossless data transmission

Telemetry-based Network Monitoring and Automated O&M, Making Management Simple and Efficient

The switch enabled with Telemetry/gRPC/sFlow/SPAN provides clear data status and hierarchy.
The switch uses the push mode to proactively collect and push information and to provide sub-second-level network monitoring in real time, making network management more efficient and accurate.

FAQ

Tips: Product information and performance will be affected by upgrade iteration, specific environment and other factors, so FAQ content is for reference only. For further information, please contact online support.

Documents

Specifications

Hardware Specifications

System Specifications

RG-S6510-48VS8CQ

Ports

48 × 25GE ports and 8 × 100GE ports

Expansion Module Slots

Power module slots

Fan module slots

Management Port

One management port, one console port, and one USB port, compliant with the USB2.0 standard

Switching Capacity

4.0Tbps

Packet Forwarding Rate

2000 Mpps

802.1Q VLAN

4094

Dimensions and Weight

RG-S6510-48VS8CQ

Dimensions

(W × D × H)

442 mm × 387 mm × 44 mm, 1 RU

Weight

About 8 kg (including two power supply modules and four fan modules)

Power Supply and Consumption

RG-S6510-48VS8CQ

AC

Rated voltage range: 100 VAC to 240 VAC

Maximum voltage range: 90 VAC to 264 VAC

Frequency: 50 Hz to 60 Hz

Rated input current range: 3.5 A to 7.2 A

High-voltage DC

Input voltage range: 192 VDC to 288 VDC

Input current: 3.6 A

Low-voltage DC

Input voltage range: –42 VDC to –72 VDC

Rated input voltage: –48 VDC

Rated input current: 23 A

Maximum Power Consumption

< 300 W

Environment and Reliability

RG-S6510-48VS8CQ

Operating Temperature

0°C to 45°C

Operating Humidity

10%–90% RH (Non-condensing)

 

Software Specifications

Software Specifications

RG-S6510-48VS8CQ

L2 Protocols

IEEE802.3ad (Link Aggregation Control Protocol), IEEE802.1p, IEEE802.1Q, IEEE802.1D (STP), IEEE802.1w (RSTP), IEEE802.1s (MSTP), IGMP Snooping, MLD Snooping, Jumbo Frame (9 KB), IEEE802.1ad (QinQ and Selective QinQ), GVRP

L3 Protocols (IPv4)

BGP4, OSPFv2, RIPv1, RIPv2, MBGP, LPM Routing, Policy-based Routing (PBR), Route-policy, Equal-Cost Multi-Path Routing (ECMP), WCMP, VRRP, IGMP v1/v2/v3, DVMRP, PIM-SSM/SM/DM, MSDP, Any-RP

IPv6 Basic Protocols

Neighbor Discovery, ICMPv6, Path MTU Discovery, DNSv6, DHCPv6, ICMPv6, ICMPv6 redirection, ACLv6, TCP/UDP for IPv6, SNMP v6, Ping/Traceroute v6, IPv6 RADIUS, Telnet/SSH v6, FTP/TFTP v6, NTP v6, IPv6 MIB support for SNMP, VRRP for IPv6, IPv6 QoS

IPv6 Features

Static routing, ECMP, PBR, OSPFv3, RIPng, BGP4+, MLDv1/v2, PIM-SMv6, manual tunnel, automatic tunnel, IPv4 over IPv6 tunnel, and ISATAP tunnel

Data Center Features

VXLAN routing and VXLAN bridging

IPv6 VXLAN over IPv4 and EVPN VXLAN

PFC, ECN, and RDMA

M-LAG

OpenFlow 1.3

Visualization

gRPC

sFLOW sampling

INT

QoS

Mapping of IEEE 802.1p, DSCP, and ToS priorities
ACL-based traffic classification
Priority marking/remarking
Multiple queue scheduling mechanisms, including SP, WRR, DRR, SP+WRR, and SP+DRR
Congestion avoidance mechanisms such as WRED and tail discarding

Virtualization

Virtual Switching Unit

Cache Management

Cache status monitoring and management, and identification of burst traffic

HA Design

GR for RIP/OSPF/BGP, BFD, DLDP, REUP dual-link fast switching, RLDP unidirectional link detection, 1+1 power redundancy and fan redundancy, and hot swapping for all cards and power supply modules

Security Features

Network Foundation Protection Policy (NFPP), CPP, DDoS attack defense, illegitimate data packet detection, data encryption, source IP spoofing prevention, IP scanning prevention, RADIUS/TACACS, IPv4/v6 packet filtering by basic ACL, extended ACL or VLAN-based ACL, plaintext-based and MD5 ciphertext-based authentication for OSPF, RIPv2, and BGPv4 packets, telnet login and password mechanisms for restricted IP addresses, uRPF, broadcast packet suppression, DHCP Snooping, ARP spoofing prevention, ARP check, and hierarchical user management

Management Mode

SNMP v1/v2/v3, Netconf, telnet, console, MGMT, RMON, SSHv1/v2, FTP/TFTP, NTP clock, Syslog, SPAN/RSPAN/ERSPAN, Telemetry, ZTP, Python, fan and power alarm, and temperature alarm

Other Protocols

DHCP Client, DHCP Relay, DHCP Server, DNS Client, UDP relay, ARP Proxy, and Syslog

Order Information

Chassis

Product Model

Description

RG-S6510-48VS8CQ

48 × 25GE ports and 8 × 100GE ports.
Two power supply module slots and four fan module slots.
The power module model is RG-PA550I-F, and the fan model is M6510-FAN-F.

RG-S6510-32CQ

Provides 32 × 100G ports.
Two power supply module slots and five fan module slots.
The power module model is RG-PA550I-F, and the fan model is M1HFAN I-F.

 

Fan and Power Supply Modules

Product Model

Description

RG-PA550I-F

550 W power supply module (AC and 240 V HVDC)

RG-PD800I-F

800 W power supply module (48 V LVDC), applicable only to RG-S6510-48VS8CQ

M6510-FAN-F

Fan module of RG-S6510-48VS8CQ, supporting 3+1 redundancy, hot swapping, and front-to-rear ventilation design.

M1HFAN I-F

Fan module of RG-S6510-32CQ, supporting 4+1 redundancy, hot swapping, and front-to-rear ventilation design.

 

Optical Transceivers

Product Model

Description

100G-QSFP-SR-MM850

100GE SR optical transceiver, QSFP28 package, MPO connector (850 nm wavelength)
The transmission distance is 100 m when OM4 optical fibers are used.

100G-QSFP-LR4-SM1310

100GE LR single-mode optical transceiver, QSFP28 package, LC connector (used in combination with LC optical fibers, 2-core, 1310 nm wavelength), maximum transmission distance of 10 km

100G-QSFP-iLR4-SM1310

100GE iLR optical transceiver, QSFP28 package, LC connector (used in combination with LC optical fibers, 2-core, 1310 nm wavelength), maximum transmission distance of 2 km

100G-AOC-10M

100GE QSFP28 port cable (including modules at both ends), with a length of 10 m

40G-QSFP-SR-MM850

40GE SR optical transceiver, QSFP+ package, MPO connector (used in combination with OM3/OM4 MPO optical fibers, 8-core/12-core, 850 nm wavelength)
The transmission distance is 100 m when OM3 optical fibers are used and 150 m when OM4 optical fibers are used.

40G-QSFP-LR4-SM1310

40GE LR single-mode optical transceiver, QSFP+ package, LC connector (used in combination with LC optical fibers, 2-core, 1310 nm wavelength), maximum transmission distance of 10 km

40G-QSFP-LSR-MM850

40GE SR optical transceiver, QSFP+ package, MPO connector (used in combination with OM3/OM4 MPO optical fibers, 8-core/12-core, 850 nm wavelength)
The transmission distance is 300 m when OM3 optical fibers are used and 400 m when OM4 optical fibers are used. One port can be split into four ports to support the 10GE SFP+ transceiver.

VG-SFP-AOC5M

25GE SFP28 optical cable (including modules on both sides), 5 m

XG-SFP-SR-MM850

10GE SR optical transceiver (300 m), applicable to SFP+ ports

XG-SFP-LR-SM1310

10GE LR optical transceiver (10 km), applicable to SFP+ ports

XG-SFP-ER-SM1550

10GE ER optical transceiver (40 km), applicable to SFP+ ports

XG-SFP-ZR-SM1550

10GE ZR optical transceiver (80 km), applicable to SFP+ ports

Ruijie Networks websites use cookies to deliver and improve the website experience.

See our cookie policy for further details on how we use cookies and how to change your cookie settings.

Cookie Manager

When you visit any website, the website will store or retrieve the information on your browser. This process is mostly in the form of cookies. Such information may involve your personal information, preferences or equipment, and is mainly used to enable the website to provide services in accordance with your expectations. Such information usually does not directly identify your personal information, but it can provide you with a more personalized network experience. We fully respect your privacy, so you can choose not to allow certain types of cookies. You only need to click on the names of different cookie categories to learn more and change the default settings. However, blocking certain types of cookies may affect your website experience and the services we can provide you.

  • Performance cookies

    Through this type of cookie, we can count website visits and traffic sources in order to evaluate and improve the performance of our website. This type of cookie can also help us understand the popularity of the page and the activity of visitors on the site. All information collected by such cookies will be aggregated to ensure the anonymity of the information. If you do not allow such cookies, we will have no way of knowing when you visited our website, and we will not be able to monitor website performance.

  • Essential cookies

    This type of cookie is necessary for the normal operation of the website and cannot be turned off in our system. Usually, they are only set for the actions you do, which are equivalent to service requests, such as setting your privacy preferences, logging in, or filling out forms. You can set your browser to block or remind you of such cookies, but certain functions of the website will not be available. Such cookies do not store any personally identifiable information.

Accept All

View Cookie Policy Details

Contact Us

Contact Us

How can we help you?

Contact Us

Get an Order help

Contact Us

Get a tech support