Compare Products
Hide
VS
Core or aggregation switch for small and medium-sized networks, supporting the smooth evolution to 25G campus networks
Models
Series
Highlight Features
The VSU connects to peripherals through an aggregate link, realizing service switching in milliseconds upon a failure.
Power modules can be replaced without affecting device operation. Intelligent fan speed regulation is supported for efficient cooling,
providing dual protection for the network.
The hardware supports dual stack for high-speed switching, catering to the requirements of campus network transition from IPv4 protocol to IPv6 protocol,
with significant improvement in address table capacity and network security.
Large amounts of data from different sources are handled by CPP first to prevent direct attacks on the CPU, ensuring CPU stability under high usage,
and achieving significant improvement in the device's security performance.
Model |
RG-S6150-24VS8CQ-X |
RG-S6150-48VS8CQ-X |
||
Basic Features |
||||
Ports and Modules |
24 x 10G/25G SFP28 ports 8 x 40G/100G QSFP28 ports 4 fan modules 2 hot-swappable power supply modules |
48 x 10G/25G SFP28 ports 8 x 40G/100G QSFP28 ports 4 fan modules 2 hot-swappable power supply modules |
||
Management Ports |
One MGMT port, one console port, and one USB port (compliant with the USB 2.0 standard) |
|||
Switching Capacity |
2.8 Tbps
|
4 Tbps
|
||
Packet Forwarding Rate |
1024Mpps/1680Mpps |
1024Mpps/2800Mpps |
||
Power Consumption (Full Load) |
270 W |
300 W |
||
Product Features |
||||
VLAN |
4K 802.1Q VLAN Port-based VLAN Private VLAN Voice VLAN GVRP |
|||
QinQ |
Basic QinQ Selective QinQ |
|||
Link Aggregation |
LACP (802.3ad) |
|||
Spanning Tree Protocols |
STP, RSTP, MSTP |
|||
DHCP |
DHCP server DHCP client DHCP snooping DHCP relay IPv6 DHCP server IPv6 DHCP snooping IPv6 DHCP client IPv6 DHCP relay |
|||
IPv6 Basic Protocols |
IPv6 addressing, Neighbor Discovery (ND), ICMPv6, Stateless Auto Configuration, Path MTU Discovery |
|||
IP Routing |
Static routing RIP, RIPng OSPFv2, OSPFv3, IS-ISv4, IS-ISv6 BGP4, BGP4+ ECMP Packet-based and flow-based load balancing MCE |
|||
Multicast |
IGMP v1, IGMPv2, IGMPv3, IGMP proxy IGMP v1/v2/v3 snooping IGMP filtering, IGMP immediate leave PIM-DM, PIM-SM, PIM-SSM MLD snooping, MLD PIM for IPv6 |
|||
MPLS |
MPLS L3VPN |
|||
ACL & QoS |
ACL |
The following flexible and diversified hardware ACLs are supported: Standard IP ACLs (IP-based hardware ACLs) Extended IP ACLs (hardware ACLs based on IP addresses or TCP/UDP port IDs) MAC-based extended ACLs (hardware ACLs based on source MAC addresses, destination MAC addresses, and optional Ethernet type) Time-based ACLs Expert-level ACLs (hardware ACLs based on flexible combinations of the Ethernet type, MAC address, IP address, TCP/UDP port ID, protocol type, and time) ACL 80 IPv6 ACLs |
||
QoS |
Port traffic identification Port traffic rate limiting 802.1p/DSCP/ToS traffic classification Eight priority queues per port SP, DRR, SP+DRR, RED/WRED queue scheduling mechanisms |
|||
Security Features |
3-tuple binding (IP address, MAC address, and port) 3-tuple binding (IPv6 address, MAC address, and port) Filtering of invalid MAC addresses Port- and MAC-based 802.1x authentication MAB authentication Portal authentication and Portal 2.0 authentication ARP check DAI ARP packet rate limiting Gateway ARP spoofing prevention Broadcast storm suppression Hierarchical management of administrators and password protection RADIUS and TACACS+ AAA (IPv4/IPv6) for device login management SSH BPDU guard IP source guard CPP, NFPP Port protection |
|||
Management Features |
SNMP, CLI (Telnet/Console), RMON, SSH, Syslog, NTP/SNTP, SNMP over IPv6, IPv6 MIB support for SNMP, SSHv6, Telnet v6, FTP/TFTP v6, DNS v6, NTP for v6, Traceroute v6 sFlow, which utilizes the random sampling technology to conduct flow information sampling on the traffic of a switch. MACC-based management |
|||
High Reliability |
VSU (virtualizing multiple devices into one device) GR for RIP, OSPF, BGP, and other routing protocols BFD ERPS (G.8032) REUP RLDP 1+1 power redundancy Hot swapping of power modules |
|||
Physical Features |
|
|||
Power Supply |
AC input: Rated voltage range: 100 V AC to 240 V AC Maximum voltage range: 90 V AC to 264 V AC Frequency: 50/60 Hz
HVDC input: Rated voltage: 240 V DC Maximum voltage range: 192 V DC to 288 V DC |
|||
Fan |
3+1 redundancy, at least three fan modules are required for the system. Fan speed regulating and fault alarming |
|||
Temperature Alarming |
Supported |
|||
Temperature |
Operating temperature: 0°C to 45°C (32°F to 113°F) Storage temperature: –40°C to 70°C (–40°F to 158°F) |
|||
Humidity |
Operating humidity: 10% to 90% (non-condensing) Storage humidity: 5% to 95% |
The switch, expansion module, power module, and other components can be ordered as needed. Before ordering an expansion module or power module, please contact the online customer service personnel for the latest support information about the module.
Model |
Description |
RG-S6150-24VS8CQ-X |
24 x 10G/25G SFP28 ports (default: 10G; the rate can be increased to 25G with a license.) 8 x 40G/100G QSFP28 ports 4 fan modules 2 power supply module slots At least one RG-PA550I II-F power supply module needs to be purchased. |
RG-S6150-48VS8CQ-X |
48 x 10G/25G SFP28 ports (default: 10G; the rate can be increased to 25G with a license.) 8 x 40G/100G QSFP28 ports 4 fan modules 2 power supply module slots At least one RG-PA550I II-F power supply module needs to be purchased. |
RG-PA550I II-F |
550 W AC power supply module |
Mini-GBIC-GT |
1000BASE-GT mini GBIC module |
XG-SFP-SR-MM850 |
10G LC interface module (62.5/125 μm: 33 m; 50/125 μm: 66 m; 300-meter transmission at modal bandwidth of 2000 MHz·km), applicable to SFP+ ports |
XG-SFP-LR-SM1310 |
10G LC interface module (1310 nm), 10 km, applicable to SFP+ ports |
XG-SFP-ER-SM1550 |
10G LC interface module (1550 nm), 40 km, applicable to SFP+ ports |
XG-SFP-AOC1M |
10G SFP+ fiber-optic cable, 1 m, including one cable and two interface modules |
XG-SFP-AOC3M |
10G SFP+ fiber-optic cable, 3 m, including one cable and two interface modules |
XG-SFP-AOC5M |
10G SFP+ fiber-optic cable, 5 m, including one cable and two interface modules |
VG-SFP-SR-MM850 |
25G SFP28 module, MMF, max cabling distance: 100 m |
VG-SFP-SR-MM1310 |
25G SFP28 module, SMF, max cabling distance: 10 km |
VG-SFP-AOC5M |
25G Base SFP+ fiber-optic cable (including modules on both ends), 5 m |
40G-QSFP-SR-MM850 |
40G SR multi-mode fiber module, applicable to QSFP+ ports (OM3/OM4 MPO connector, 8 core, 850-nm wave length, max cabling distance: 100 m(OM3), 150 m(OM4)) |
40G-QSFP-LR4 SM1310 |
40G LR single-mode fiber module, applicable to QSFP+ ports, max cabling distance:10 km (LC interface, 2 core, 1310-nm wave length) |
40G-AOC-5M |
40G QSFP+ fiber-optic cable, 5 m, including one cable and two interface modules |
40G-AOC-10M |
40G QSFP+ fiber-optic cable, 10 m, including one cable and two interface modules |
100G-QSFP-SR-MM850 |
100G SR fiber module, QSFP28 encapsulation, MPO connector, 850-nm wave length, max cabling distance: 100 m(OM4), 70 m (OM3) |
100G-QSFP-LR4-SM1310 |
100G LR fiber module, QSFP28 encapsulation, LC interface, 1310-nm wave length, max cabling distance: 10 km (SMF) |
100G-AOC-1M |
100G QSFP28 fiber-optic cable, 1 m, including one cable and two interface modules |
100G-AOC-5M |
100G QSFP28 fiber-optic cable, 5 m, including one cable and two interface modules |
100G-AOC-10M |
100G QSFP28 fiber-optic cable, 10 m, including one cable and two interface modules |
Ruijie Networks websites use cookies to deliver and improve the website experience.
See our cookie policy for further details on how we use cookies and how to change your cookie settings.
Cookie Manager
When you visit any website, the website will store or retrieve the information on your browser. This process is mostly in the form of cookies. Such information may involve your personal information, preferences or equipment, and is mainly used to enable the website to provide services in accordance with your expectations. Such information usually does not directly identify your personal information, but it can provide you with a more personalized network experience. We fully respect your privacy, so you can choose not to allow certain types of cookies. You only need to click on the names of different cookie categories to learn more and change the default settings. However, blocking certain types of cookies may affect your website experience and the services we can provide you.
Through this type of cookie, we can count website visits and traffic sources in order to evaluate and improve the performance of our website. This type of cookie can also help us understand the popularity of the page and the activity of visitors on the site. All information collected by such cookies will be aggregated to ensure the anonymity of the information. If you do not allow such cookies, we will have no way of knowing when you visited our website, and we will not be able to monitor website performance.
This type of cookie is necessary for the normal operation of the website and cannot be turned off in our system. Usually, they are only set for the actions you do, which are equivalent to service requests, such as setting your privacy preferences, logging in, or filling out forms. You can set your browser to block or remind you of such cookies, but certain functions of the website will not be available. Such cookies do not store any personally identifiable information.
Contact Us
How can we help you?