Compare Products
Hide
VS
Aggregation switch for large-sized networks, or core switch for small and medium-sized networks
Models
Series
Highlight Features
Hardware Specifications |
RG-S5760C-24GT8XS-X |
RG-S5760C-48GT4XS-X |
RG-S5760C-24SFP8GT8XS-X |
RG-S5760C-48SFP4XS-X |
RG-S5760C-48GT4XS-HP-X |
Interface Specifications |
|||||
Fixed port |
24 x 10/100/1000 Mbps electrical ports with auto-negotiation, 8 x 1GE/10GE SFP+ ports, 2 x power supply module slots |
48 x 10/100/1000 Mbps electrical ports with auto-negotiation, 4 x 1GE/10GE SFP+ ports, 2 x power supply module slots |
24 x 1000 Mbps SFP ports (Ports 1-16 are 100/1000 Mbps SFP ports), 8 x 10/100/1000 Mbps combo ports with auto-negotiation, 8 x 1GE/10GE SFP+ ports, 2 x power supply module slots |
48 x 1000 Mbps SFP ports, 4 x 1GE/10GE SFP+ ports, 3 x modular fans, 2 x power supply module slots |
48 x 10/100/1000 Mbps electrical ports with auto-negotiation, 4 x 1GE/10GE SFP+ ports, 2 x power supply module slots, supporting PoE/PoE+ |
Fan module |
Two built-in fan modules Fan speed regulating and fault alarms |
Three pluggable fan modules |
Two pluggable fan modules |
||
Power module |
Two power modules The switch can be powered on by either one or dual power modules. If both power modules are used, the switch works in the power redundancy mode. |
||||
Management port |
One MGMT port, one console port, and one USB port, compliance with the USB2.0 standard |
||||
Expansion slot |
Two expansion slots are reserved for expansion modules and supervisor modules. One expansion slot is reserved on the RG-S5760C-48GT4XS-HP-X and RG-S5760C-48SFP4XS-X. |
||||
System Specifications |
|||||
Packet forwarding rate |
426Mpps/660Mpps |
406Mpps/660Mpps |
426Mpps/660Mpps |
406Mpps/660Mpps |
406Mpps/660Mpps |
Switching capacity |
7.92Tbps |
7.92Tbps |
7.92Tbps |
7.92Tbps |
7.92Tbps |
Number of MAC addresses |
128,000 |
128,000 |
128,000 |
128,000 |
128,000 |
ARP table size |
24,000 |
24,000 |
24,000 |
24,000 |
24,000 |
Number of IPv4 unicast routes |
24,000 |
24,000 |
24,000 |
24,000 |
24,000 |
Number of IPv4 multicast routes |
4,000 mmu-enhance: 3,000 |
4,000 mmu-enhance: 3,000 |
4,000 mmu-enhance: 3,000 |
4,000 mmu-enhance: 3,000 |
4,000 mmu-enhance: 3,000 |
Number of IPv6 unicast routes |
14,000 |
14,000 |
14,000 |
14,000 |
14,000 |
Number of IPv6 multicast routes |
2,000 mmu-enhance: 1,500 |
2,000 mmu-enhance: 1,500 |
2,000 mmu-enhance: 1,500 |
2,000 mmu-enhance: 1,500 |
2,000 mmu-enhance: 1,500 |
Number of ACEs |
In: 7,000 Out:1,500 |
||||
Number of IGMP groups |
4,000 |
||||
Number of MLD groups |
1,000 |
||||
Number of VSU members |
4 |
||||
Dimensions and Weight |
|||||
Dimensions (W x D x H) |
440 mm x 340 mm x 44 mm (17.32 in. x 13.39 in. x 1.73 in.) |
442 mm x 420 mm x 43.6 mm (17.40 in. x 16.54 in. x 1.72 in.) |
|||
Weight |
4.4 kg (9.70 lbs) |
4.5 kg (9.92 lbs) |
4.3 kg (9.48 lbs) |
5.3 kg (11.68 lbs) |
5.5 kg (12.13 lbs) |
CPU and Storage |
|||||
CPU |
1.2 GHz dual-core CPU |
||||
Storage |
Flash memory: 4 GB SDRAM: 1 GB |
Flash memory: 4 GB SDRAM: 2 GB |
|||
Data packet buffer |
1.2MB |
||||
Power and Consumption |
|||||
Maximum power consumption |
< 60 W (excluding expansion modules) < 85 W (including expansion modules) |
< 70 W (excluding expansion modules) < 95 W (including expansion modules) |
< 77 W (excluding expansion modules) < 102 W (including expansion modules) |
< 105 W (excluding expansion modules) < 125 W (including expansion modules) |
Without PoE load: ≤ 110 W With PoE full load: ≤ 1,590 W |
Maximum output power |
RG-PA70IB: 70 W RG-PA150I-F: 150 W RG-PA150IB-F: 100 V to 240 V, 150 W RG-PD150IB-F: 48 V DC to 60 V DC, 150 W |
RG-PA70IB: 70 W RG-PA150I-F: 150 W RG-PA150IB-F: 100 V to 240 V, 150 W RG-PD150IB-F: 48 V DC to 60 V DC, 150 W |
RG-PA150I-F: 150 W RG-PA150IB-F: 100 V to 240 V, 150 W RG-PD150IB-F: 48 V DC to 60 V DC, 150 W |
RG-PA150I-F: 150 W RG-PA150IB-F: 100 V to 240 V, 150 W RG-PD150IB-F: 48 V DC to 60 V DC, 150 W |
RG-PA600I-P-F: 600 W (PoE: 370 W) RG-PD600I-P-F: 600 W (PoE: 370 W) RG-PA1000I-P-F: 176 V AC to 290 V AC, 1000 W; 90 V AC to 176 V AC, 930 W (PoE: 740 W) |
Rated input voltage |
AC input Rated voltage range: 100 V to 240 V Frequency: 50 Hz/60 Hz HVDC input: Rated voltage range: 240 V LVDC input: Rated voltage range: 48 V DC to 60 V DC |
AC input Rated voltage range: 200 V to 240 V Frequency: 50 Hz/60 Hz DC input: Rated voltage range: 48 V to 60 V |
AC input Rated voltage range: 200 V to 240 V Frequency: 50 Hz/60 Hz DC input: Rated voltage range: 48 V to 60 V |
||
Maximum input voltage |
AC input Maximum voltage range: 90 V to 264 V HVDC input: Maximum voltage range: 192 V to 288 V LVDC input: Maximum voltage range: 36 V DC to 75 V DC |
AC input Maximum voltage range: 176 V to 264 V DC input: Maximum voltage range: 38 V to 75 V |
AC input Maximum voltage range: 90 V to 264 V DC input: Maximum voltage range: 36 V to 75 V |
||
Environment and Reliability |
|||||
MTBF |
120 years |
110 years |
94 years |
90 years |
95 years |
Primary Airflow |
Air intake from left and front panel, and air exhaust from right |
Front-to-rear airflow |
|||
Operating temperature |
0°C to 45°C (32°F to 113°F) V1.X+M5000X4XS2CQ: 0 to 40°C (32°F to 104°F) |
0°C to 45°C (32°F to 113°F) |
|||
Storage temperature |
–40°C to +70°C (–40°F to +158°F) |
||||
Operating humidity |
10% to 90% (non-condensing) |
||||
Storage humidity |
5% to 95% (non-condensing) |
||||
Operating altitude |
0 m to +5,000 m (0 ft. to +16404.20 ft.) |
||||
Operating noise |
45°C (113°F): 56.2 dB |
45°C (113°F): 57.9 dB |
45°C (113°F): 57.1 dB |
27°C (80.6°F): 50 dB 45°C (113°F): 65 dB |
27°C (80.6°F): 53 dB 45°C (113°F): 68 dB |
Interface surge protection |
Power port: 6 kV Telecom port: 10 kV (MGMT port: 4 kV) |
RG-S5760-X Series |
|
Feature |
Description |
Ethernet switching |
Jumbo frame (maximum length: 9,216 bytes) |
IEEE 802.1Q (supporting 4K VLANs) |
|
Voice VLAN |
|
Super-VLAN and private VLAN |
|
MAC address-based, port-based, protocol-based, and IP subnet-based VLAN assignment |
|
GVRP |
|
Basic QinQ and selective QinQ |
|
STP, RSTP, and MSTP |
|
ERPS (G.8032) |
|
LLDP/LLDP-MED |
|
LACP (IEEE 802.3ad) |
|
IP service |
ARP |
DHCP client, DHCP relay, and DHCP server |
|
DHCP snooping |
|
DNS |
|
DHCPv6 client, DHCPv6 server, and DHCPv6 relay |
|
DHCPv6 snooping |
|
Neighbor Discovery (ND) and ND snooping |
|
IPV6 addressing, ICMPv6, Stateless Address Auto-configuration (SLAAC), and path MTU discovery |
|
IP routing |
Static routing |
RIP and RIPng |
|
OSPFv2, OSPFv3, IS-ISv4, ISv4, and IS-ISv6 |
|
BGP4 and BGP4+ |
|
ECMP |
|
IPv4 and IPv6 VRF |
|
IPv4 and IPv6 PBR |
|
Multicast |
IGMP v1/v2/v3 and IGMP proxy |
IGMP v1/v2/v3 snooping |
|
IGMP filtering and IGMP fast leave |
|
PIM-DM, PIM-SM, and PIM-SSM |
|
MSDP |
|
MLD snooping v1/v2 |
|
PIM-SMv6 and PIM-SSM v6 |
|
MPLS |
MPLS L3VPN |
ACL and QoS |
Standard IP ACLs Extended IP ACLs Extended MAC ACLs Time-based ACLs Expert-level ACLs ACL80 IPv6 ACL |
ACL redirection |
|
Port traffic identification |
|
Port traffic rate limiting |
|
Congestion management: SP, WRR, DRR, WFQ, SP+WRR, SP+DRR, and SP+WFQ |
|
Congestion avoidance: tail drop, RED, and WRED |
|
802.1p/DSCP/ToS traffic classification Eight priority queues per port |
|
Security |
AAA |
RADIUS and TACAS+ |
|
Port-based and MAC address-based 802.1X authentication |
|
Web authentication |
|
HTTPS |
|
SSHv1 and SSHv2 |
|
Global IP-MAC binding |
|
Port isolation and port security |
|
IP source guard |
|
SAVI |
|
CPP and NFPP |
|
Strict and loose RPF uRPF ignoring default routes |
|
3-tuple binding (IP address, MAC address, and port) 3-tuple binding (IPv6 address, MAC address, and port) Filtering of unauthorized MAC addresses MAC address bypass (MAB) authentication Portal authentication and Portal 2.0 authentication ARP check Dynamic ARP Inspection (DAI) ARP packet rate limiting Gateway ARP anti-spoofing Broadcast storm suppression Hierarchical management of administrators and password protection AAA for device login management MAC Authentication Bypass (SSH) BPDU guard Port protection |
|
Reliability |
REUP, RLDP, and DLDP |
IPv4 VRRP v2/v3 and IPv6 VRRP |
|
GR for RIP, OSPF, BGP, and other routing protocols |
|
BFD |
|
Link tracing, fault notification, and remote loopback based on 802.3ah (EFM) |
|
1+1 power module redundancy |
|
Hot swapping of power modules and cables |
|
3-level fan speed adjustment Fan fault alarm |
|
Device virtualization |
VSU |
NMS and mainten ance |
SPAN, RSPAN, and ERSPAN |
sFlow |
|
NTP and SNTP |
|
FTP and TFTP |
|
SNMP v1/v2c/v3 |
|
RMON (1, 2, 3, 9) |
|
SSHv1 and SSHv2 |
|
Syslog |
|
NETCONF |
|
CWMP (TR-069) |
|
gRPC |
|
CLI (Telnet/Console), SNMP over IPv6, IPv6 MIB support for SNMP, SSHv6, Telnet v6, FTP/TFTP v6, DNS v6, NTP for IPv6, and Traceroute v6 |
|
PoE |
RG-S5760C-48GT4XS-HP-E: IEEE 802.3af and 802.3at, uninterruptible power supply upon hot start, and port priority |
VXLAN |
With VXLAN, a Layer 2 logical network can be built based on a Layer 3 network through software upgrade. |
RG-S5760-X Series |
|
Organization |
Standards and Protocol |
IETF |
RFC 1157 A Simple Network Management Protocol (SNMP) RFC 1305 Network Time Protocol Version 3 (NTP) RFC 1349 Internet Protocol (IP) RFC 1350 TFTP Protocol (revision 2) RFC 1519 CIDR RFC 1591 Domain Name System Structure and Delegation RFC 1643 Ethernet Interface MIB RFC 1757 Remote Network Monitoring (RMON) RFC 1812 Requirements for IP Version 4 Router RFC 1901 Introduction to Community-based SNMPv2 RFC 1902-1907 SNMP v2 RFC 1918 Address Allocation for Private Internet RFC 2131 Dynamic Host Configuration Protocol (DHCP) RFC 2132 DHCP Options and BOOTP Vendor Extensions RFC 2571 SNMP Management Frameworks RFC 2863 The Interfaces Group MIB RFC 2925 Definitions of Managed Objects for Remote Ping, Traceroute, and Lookup Operations (Ping only) RFC 3046 DHCP Option82 RFC 3417 (SNMP Transport Mappings) RFC 3418 Management Information Base (MIB) for the Simple Network Management Protocol (SNMP) RFC 4022 MIB for TCP RFC 768 User Datagram Protocol (UDP) RFC 783 TFTP Protocol (revision 2) RFC 792 Internet Control Message Protocol (ICMP) RFC 793 Transmission Control Protocol (TCP) RFC 813 Window and Acknowledgement Strategy in TCP RFC 815 IP datagram reassembly algorithms RFC 826 Ethernet Address Resolution Protocol (ARP) RFC 854 Telnet Protocol RFC 959 File Transfer Protocol (FTP) RFC 1058 Routing Information Protocol (RIP) RFC 1583 OSPF Version 2 RFC 1981 Path MTU Discovery for IP version 6 RFC 1997 BGP Communities Attribute RFC 2236 IGMP RFC 2328 OSPF Version 2 RFC 2385 Protection of BGP Sessions via the TCP MD5 Signature Option RFC 2439 BGP Route Flap Damping RFC 2460 Internet Protocol, Version 6 (IPv6) RFC 2461 Neighbor Discovery for IP Version 6 (IPv6) RFC 2462 IPv6 Stateless Address Auto configuration RFC 2463 Internet Control Message Protocol for IPv6 (ICMPv6) RFC 2545 Use of BGP 4 Multiprotocol Extensions for IPv6 Inter Domain Routing RFC 2711 IPv6 Router Alert Option RFC 2787 Definitions of Managed Objects for the Virtual Router Redundancy Protocol RFC 2865 Remote Authentication Dial In User Service (RADIUS) RFC 2918 Route Refresh Capability for BGP 4 RFC 2934 Protocol Independent Multicast MIB for IPv4 RFC 3065 Autonomous System Confederation for BGP RFC 3101 OSPF Not so stubby area option RFC 3137 OSPF Stub Router Advertisement sFlow RFC 3509 Alternative Implementations of OSPF Area Border Routers RFC 3513 IP Version 6 Addressing Architecture RFC 3575 IANA Considerations for RADIUS RFC 3579 RADIUS Support For EAP RFC 3623 Graceful OSPF Restart RFC 3768 VRRP RFC 3810 Multicast Listener Discovery Version 2 (MLDv2) for IPv6 RFC 3973 PIM Dense Mode RFC 4271 A Border Gateway Protocol 4 (BGP 4) RFC 4273 Definitions of Managed Objects for BGP 4 RFC 4360 BGP Extended Communities Attribute RFC 4456 BGP Route Reflection: An Alternative to Full Mesh Internal BGP (IBGP) RFC 4486 Subcodes for BGP Cease Notification Message RFC 4552 Authentication/Confidentiality for OSPFv3 RFC 4724 Graceful Restart Mechanism for BGP RFC 4750 OSPFv2 MIB partial support no SetMIB RFC 4760 Multiprotocol Extensions for BGP 4 RFC 4940 IANA Considerations for OSPF RFC 5065 Autonomous System Confederation for BGP RFC 5187 OSPFv3 Graceful Restart RFC 5340 OSPFv3 for IPv6 RFC 5492 Capabilities Advertisement with BGP 4 RFC 6620 FCFS SAVI |
IEEE |
IEEE 802.2 Logical Link Control IEEE 802.1ab Link Layer Discovery Protocol IEEE 802.1ad Provider Bridges IEEE 802.1ax/IEEE802.3ad Link Aggregation IEEE 802.1D Media Access Control (MAC) Bridges IEEE 802.1Q Virtual Bridged Local Area Networks (VLAN) IEEE 802.3ad Link Aggregation Control Protocol (LACP) IEEE Std 802.3x Full Duplex and flow control IEEE 802.1D Spanning Tree Protocol IEEE 802.1s Multiple Spanning Tree Protocol IEEE 802.1w Rapid Spanning Tree Protocol IEEE 802.3bt Power over Ethernet |
|
Electromagnetic Compatibility (EMC) Standards: ✓CISPR 22/EN 55032 (Conducted and Radiated Emissions) ✓EN 55035 (Immunity) ✓IEC/EN 61000-4-2 or ANSI/ESD S20.20 (Electrostatic Discharge - ESD) ✓IEC/EN 61000-4-3 (Radio Frequency Electromagnetic Field) ✓IEC/EN 61000-4-4 (Electrical Fast Transient -EFT) ✓IEC/EN 61000-4-5 (Surge Immunity) ✓IEC/EN 61000-4-6 (Radio Frequency Common Mode) ✓IEC/EN 61000-4-11 (Voltage Dips and Interruptions) ✓IEC/EN 61000-3-2(Voltage Dips and Interruptions) ✓IEC/EN 61000-3-2 (Voltage Dips and Interruptions) • Safety Standards: ✓IEC 60950/EN 62368 ✓IEC 60068 ✓RoHS or WEEE (Environmental) |
Model |
Description |
RG-S5760C-24GT8XS-X |
24 x 10/100/1000 Mbps electrical ports with auto-negotiation, 8 x 1GE/10GE SFP+ ports, 1 x expansion slot, 2 x built-in fixed fans, 2 x power module slots Purchase at least one RG-PA150IB-F module. |
RG-S5760C-48GT4XS-X |
48 x 10/100/1000 Mbps electrical ports with auto-negotiation, 4 x 1GE/10GE SFP+ ports, 1 x expansion slot, 2 x built-in fixed fans, 2 x power module slots (Purchase at least one RG-PA150IB-F module.) |
RG-S5760C-24SFP8GT8XS-X |
24 x 10/100/1000 Mbps SFP ports (Ports 1-16 are 100/1000 Mbps SFP ports), 8 x 10/100/1000 Mbps combo ports with auto-negotiation, 8 x 1GE/10GE SFP+ ports, 1 x expansion slot, 2 x built-in fans, 2 x power module slots (Purchase at least one RG-PA150IB-F module.) |
RG-S5760C-48SFP4XS-X |
48 x 1000 Mbps SFP ports, 4 x 1GE/10GE SFP+ ports, 1 x expansion slot, 3 x modular fans, 2 x power module slots Purchase at least one RG-PA150IB-F module. |
RG-S5760C-48GT4XS-HP-X |
48 x 10/100/1000 Mbps electrical ports with auto-negotiation, 4 x 1GE/10GE SFP+ ports, 1 x expansion slot, 2 x modular fans, 2 x power module slots Purchase at least one RG-PA600I-P-F/RG-PA1000I-P-F/RG-PD600I-P-F module. |
M5000X-4XS2CQ |
4 x 10GE SFP+ ports and 2 x 100GE QSFP28 ports |
M5000X-4QXS* |
4 x 40GE QSFP+ ports |
RG-PA150IB-F |
150 W AC power module |
RG-PA600I-P-F |
600 W PoE AC power module |
RG-PA1000I-P-F |
1000 W PoE AC power module |
RG-PD600I-P-F |
600 W PoE DC power module |
Model |
Description |
Mini-GBIC-GT |
1000BASE-GT mini GBIC module |
MINI-GBIC-SX-MM850 |
Single-port 1000BASE-SX mini GBIC module (LC connector) |
MINI-GBIC-LX-SM1310 |
Single-port 1000BASE-LX mini GBIC module (LC connector) |
MINI-GBIC-LH40-SM1310 |
Single-port 1000BASE-LH mini GBIC module (LC connector), supporting a transmission distance of 40 km (24.85 miles) |
MINI-GBIC-ZX50-SM1550 |
Single-port 1000BASE-ZX mini GBIC module (LC connector), supporting a transmission distance of 50 km (24.85 miles) |
MINI-GBIC-ZX80-SM1550 |
Single-port 1000BASE-ZX mini GBIC module (LC connector), supporting a transmission distance of 80 km (24.85 miles) |
MINI-GBIC-ZX100-SM1550 |
1000BASE-ZX mini GBIC module, supporting a transmission distance of 100 km (62.14 miles) |
XG-SFP-SR-MM850 |
10GE LC module (62.5/125 μm: 33 m (108.27 ft.); 50/125 μm: 66 m (216.54 ft); transmission for 300 m (984.25 ft.) when modal bandwidth is 2000 MHz*km), applicable to SFP+ ports |
XG-SFP-LR-SM1310 |
10GE LC interface module (1310 nm), 10 km (6.21 miles), applicable to SFP+ ports |
XG-SFP-ER-SM1550 |
10GE LC interface module (1550 nm), 40 km (24.85 miles), applicable to SFP+ ports |
XG-SFP-AOC1M |
10GE SFP+ optical cable, 1 m (3.28 ft.), including one cable and two interface modules |
XG-SFP-AOC3M |
10GE SFP+ optical cable, 3 m (9.84 ft.), including one cable and two interface modules |
XG-SFP-AOC5M |
10GE SFP+ optical cable, 5 m (16.40 ft.), including one cable and two interface modules |
Ruijie Networks websites use cookies to deliver and improve the website experience.
See our cookie policy for further details on how we use cookies and how to change your cookie settings.
Cookie Manager
When you visit any website, the website will store or retrieve the information on your browser. This process is mostly in the form of cookies. Such information may involve your personal information, preferences or equipment, and is mainly used to enable the website to provide services in accordance with your expectations. Such information usually does not directly identify your personal information, but it can provide you with a more personalized network experience. We fully respect your privacy, so you can choose not to allow certain types of cookies. You only need to click on the names of different cookie categories to learn more and change the default settings. However, blocking certain types of cookies may affect your website experience and the services we can provide you.
Through this type of cookie, we can count website visits and traffic sources in order to evaluate and improve the performance of our website. This type of cookie can also help us understand the popularity of the page and the activity of visitors on the site. All information collected by such cookies will be aggregated to ensure the anonymity of the information. If you do not allow such cookies, we will have no way of knowing when you visited our website, and we will not be able to monitor website performance.
This type of cookie is necessary for the normal operation of the website and cannot be turned off in our system. Usually, they are only set for the actions you do, which are equivalent to service requests, such as setting your privacy preferences, logging in, or filling out forms. You can set your browser to block or remind you of such cookies, but certain functions of the website will not be available. Such cookies do not store any personally identifiable information.
Contact Us
How can we help you?